TY - CHAP M1 - Book, Section TI - The Basics A1 - Ferry, David R. PY - 2007 T2 - ECG in 10 Days, 2e AB - Cardiac muscle has two unique properties that predispose it to the two common types of arrhythmiasAutomaticityAs opposed to skeletal muscle, all myocardial cells exhibit spontaneous depolarization.This is normally a beneficial property because:It obviates the need for central nervous system initiation of myocardial depolarization.It allows for "backup" pacemakers to take over if there is sinus node dysfunction or failure of propagation of depolarization.Disorders of this property can result in automatic or ectopic arrhythmias.Gap junction transmissionAgain, as opposed to skeletal muscle, myocardial cells can transmit electrical signals from one to another via gap junctions.This is normally beneficial as nervous tissue is not required for the propagation of depolarization.However, as will be seen, the requirements for reentrant arrhythmias include having at least two pathways for electrical current, a condition facilitated by gap junctions.Components of the conduction systemThe conduction system consists of modified cardiac muscle cells that have unique electrical properties.Sinoatrial (SA) nodeThe SA node is a collection of cells in the upper right corner of the right atrium.The SA node controls the rhythm of the heart by virtue of having the fastest intrinsic rate of depolarization (60–100 beats/min).The SA node starts the cardiac cycle by initiating atrial systole. The atrioventricular (AV) nodeThe AV node is located near the inferior portion of the interatrial septum.The AV node serves two functions:It provides a physiological conduction delay to allow the atria to fill the ventricles prior to ventricular systole.It also protects the ventricles from excessive stimulation from the atria, such as in atrial fibrillation.The His-Purkinje systemThe His bundle divides into the right and left bundles.The left bundle further divides into the left anterior and posterior fascicles.The His-Purkinje system provides for the orderly depolarization of the ventricles.Genesis of the surface electrocardiogram (ECG)A wave of negative electric potential spreads across contracting myocardium.This potential can be detected by electrodes placed at various locations on the skin, the signal amplified, and displayed as an ECG.The components of the ECG represent various cardiac events.The P wave corresponds to atrial systole.The PR interval represents the physiological delay in the AV node and His bundle.The QRS complex results from ventricular systole.The T wave represents ventricular repolarization.The cause of the inconsistently present U wave is controversial. The ECG paperThe ECG is recorded on moving paper ruled at 1 mm intervals with darker lines every 5 mm.At the standard paper speed of 25 mm/sec, each I mm horizontally represents 40 msec and each 5 mm interval 200 msec.In the vertical dimension, each 10 mm represents 0.1 mv of electrical potential. The standard ECG leadsThere are six standard leads (the "limb leads") that depict cardiac electrical events from six angles in the frontal or vertical plane.There are six precordial leads (the "chest leads") that depict electrical events in the horizontal plane. Genesis of the ECG wave forms in the various leads and the concept of axisThe P wave, QRS complex, and T wave for any lead can be derived from the vector representation of electrical activity in the appropriate plane.For instance, ventricular depolarization in the frontal plane can ... SN - PB - McGraw-Hill Education CY - New York, NY Y2 - 2024/03/29 UR - accesscardiology.mhmedical.com/content.aspx?aid=1128941604 ER -