Skip to Main Content

++

PATIENT STORY

++

A 75-year-old man was sent to the noninvasive vascular laboratory for evaluation of patency of his palmar arch prior to possible harvesting of his radial artery (RA) for use as an autograft in a coronary artery bypass procedure. His saphenous veins and one of his internal mammary arteries had been previously used.

++

ANATOMY AND PHYSIOLOGY

++

  • A dual system consisting of the superficial and deep palmar arches formed by the radial and ulnar arteries (UAs) supplies blood flow to the hand in most people.

  • Rarely, there is a third artery, the median artery supplying the hand.

  • A patent UA and a physiologically complete palmar arch network are necessary for safe harvesting of the RA.

  • The UA commonly forms the superficial palmar arch in conjunction with the superficial palmar branch of the RA. This arch is complete in 84.4% of people.1

  • The deep palmar arch is most often formed by an anastomosis between the deep palmar branch of the UA and the dorsal RA.

++

THE ALLEN TEST

++

  • Edgar V. Allen first described the Allen test in1929 when reporting three patients with thromboangiitis obliterans.2

  • His original description of making a fist with the RA occluded for 1 minute followed by extending the fingers and watching for return of color was later modified and is now called the modified Allen test (MAT).3

  • The correct technique involves the patient making a fist for 30 seconds while pressure is applied over both the radial and ulnar arteries to occlude them. The patient is then asked to open the fist and the UA is selectively released with the RA still occluded.

  • Hyperextension of the hand or wide separation of the digits is avoided to avoid a falsely positive abnormal test. In most normal hands it takes 3 to 12 seconds for the normal color to return if sufficient collateral to the hand is present.4

  • The MAT is considered positive or abnormal if color does not return in this time interval.

++

CLINICAL SIGNIFICANCE

++

  • The RA is the third most common conduit utilized for grafting of coronary artery occlusive disease. Cardiac surgeons need precise information of adequate collateral circulation to the hand to avoid harvesting the RA if this would result in hand ischemia with devastating consequences.

  • Furthermore, if prolonged RA catheterization or larger bore lines are inserted with a greater risk of thrombosis, demonstration of a physiologically complete palmar arch is necessary.

  • The specificity of the MAT is in the 97% range with a 6-second cutoff.5

  • The predictive value of a positive (abnormal) MAT is such that it does not necessarily mean hand ischemia will result if the RA is harvested.

  • A negative (normal) MAT safely allows RA harvest, although the cutoff point is somewhat controversial and can range between 3 and 12 seconds.

  • Because of the lower sensitivity if a MAT is ...

Want remote access to your institution's subscription?

Sign in to your MyAccess profile while you are actively authenticated on this site via your institution (you will be able to verify this by looking at the top right corner of the screen - if you see your institution's name, you are authenticated). Once logged in to your MyAccess profile, you will be able to access your institution's subscription for 90 days from any location. You must be logged in while authenticated at least once every 90 days to maintain this remote access.

Ok

About MyAccess

If your institution subscribes to this resource, and you don't have a MyAccess profile, please contact your library's reference desk for information on how to gain access to this resource from off-campus.

Subscription Options

AccessCardiology Full Site: One-Year Subscription

Connect to the full suite of AccessCardiology content and resources including textbooks such as Hurst's the Heart and Cardiology Clinical Questions, a unique library of multimedia, including heart imaging, an integrated drug database, and more.

$595 USD
Buy Now

Pay Per View: Timed Access to all of AccessCardiology

24 Hour Subscription $34.95

Buy Now

48 Hour Subscription $54.95

Buy Now

Pop-up div Successfully Displayed

This div only appears when the trigger link is hovered over. Otherwise it is hidden from view.